Transmission rate
|
|
Transfer rate
|
|
|
10 ... 100 Mbit/s
|
Interfaces
|
|
Number of electrical connections
|
|
|
2
|
Type of electrical connection
|
|
|
RJ45 port / 15-pin ITP connection
|
Supply voltage, current consumption, power loss
|
|
Type of voltage of the supply voltage
|
DC
|
Supply voltage
|
|
|
5 V
|
|
12 V
|
Relative symmetrical tolerance for DC
|
|
|
5 %
|
|
5 %
|
Consumed current
|
|
|
0.45 A
|
|
0.5 A
|
Active power loss
|
4 W
|
Permitted ambient conditions
|
|
Ambient temperature
|
|
|
5 ... 55 °C
|
|
-20 ... +60 °C
|
|
-20 ... +60 °C
|
Relative humidity at 25 °C without condensation during operation maximum
|
95 %
|
Protection class IP
|
IP00
|
Design, dimensions and weight
|
|
Module format
|
PCI
|
Width
|
21.6 mm
|
Height
|
107 mm
|
Depth
|
167 mm
|
Net weight
|
140 g
|
Number of plug-in cards of same design plug-in per PC station
|
4
|
Number of units Note
|
-
|
Performance data
|
|
Performance data open communication
|
|
Software for open communication by means of SEND/RECEIVE required
|
Yes, HARDNET-IE S7 (S7-1613)
|
Number of possible connections for open communication by means of SEND/RECEIVE maximum
|
120
|
Performance data S7 communication
|
|
Software for S7 communication required
|
Yes, HARDNET-IE S7 (S7-1613)
|
Number of possible connections for S7/PG communication maximum
|
120
|
Number of possible connections for optimized S7 communication maximum
|
40
|
Performance data multi-protocol mode
|
|
Number of active connections with multi-protocol mode
|
120
|
Number of configurable connections per PC station
|
207
|
Performance data PROFINET CBA
|
|
Software for PROFINET CBA communication required
|
Yes, PN CBA OPC server
|
Number of remote connection partners with PROFINET CBA
|
228
|
Number of connections with PROFINET CBA total
|
10 000
|
Product functions management, configuration
|
|
Product function MIB support
|
Yes
|
Protocol is supported
|
|
|
Yes
|
|
No
|
|
Yes
|
|
No
|
Configuration software required
|
Included in the scope of delivery of the required software product
|
Configuration software for PROFINET CBA required
|
Yes, SIMATIC iMAP
|
Identification & maintenance function
|
|
|
Yes
|
|
Yes
|
|
No
|
|
No
|
|
No
|
Product functions Redundancy
|
|
Software for redundancy function required
|
Yes, HARDNET-IE S7-REDCONNECT for communication with SIMATIC S7 H systems
|
Product functions Time
|
|
Product function SICLOCK support
|
Yes
|
Protocol is supported NTP
|
No
|
Standards, specifications, approvals
|
|
Standard
|
|
|
2004/108/EC
|
|
CAN/CSA C22.2 & UL 60950-1, UL 1950
|
|
EN 61000-6-3, EN 61000-6-4
|
|
EN 61000-6-1, EN 61000-6-2
|
Certificate of suitability
|
|
|
Yes
|
|
Yes
|