Product Info
|
|
400 Watt AC-DC Front End Power Supply
Single Output, 90-265 Vac Input. Active Power Factor Correction and Isolated DC Output Module. 47-440 Hz
|
|
Features
|
Meets All Requirements of MIL-STD-1399
|
Meets CE101 and CE102 of MIL-STD-461.
|
Meets MIL-STD-704E and MIL-STD-810
|
Non-latching Over Temperature Protection
|
Latching Output Overvoltage Protection
|
Isolated AC/ Good TTL Signal
|
Isolated Output DC Good TTL Signal
|
Isolated 13 VDC Standby Output
|
Fully rated 400 Watts of output power from 90 - 265 Vac
|
Environmental Screening available
|
|
Input Characteristics
|
Min
|
Max
|
Typical
|
Units/Comments
|
Input Voltage Range
|
90
|
265
|
|
VAC, 47 TO 440 Hz, 1-PHASE
|
Efficiency Range:
|
|
|
Up to 81% (28Vout, 115 Vin/60 Hz, FL
|
|
|
|
|
|
|
Output Characteristics
|
Min
|
Max
|
Typical
|
Units/Comments
|
Output Power(Max.):
|
|
400
|
|
Watts
|
Number of Outputs:
|
|
1
|
|
|
|
|
|
|
|
Model
|
Main Output Voltage (VDC)
|
Aux 1 Nom. Vout (VDC)
|
Aux 2 Nom. Vout (VDC)
|
Main Output Current (Amps)
|
Aux 1 Output Current (Amps)
|
Aux 2 Output Current (Amps)
|
MW400S/2
|
2
|
|
|
100
|
|
|
MW400S/3.3
|
3.3
|
|
|
100
|
|
|
MW400S/5
|
5
|
|
|
80
|
|
|
MW400S/12
|
12
|
|
|
33.3
|
|
|
MW400S/15
|
15
|
|
|
26.7
|
|
|
MW400S/24
|
24
|
|
|
16.7
|
|
|
MW400S/28
|
28
|
|
|
14.3
|
|
|
|
|
|
|
|
|
Line Regulation:
|
|
|
5mV Typical
|
|
Ripple/Noise:
|
|
|
60mV Typical
|
|
|
|
|
|
|
Isolation Characteristics
|
|
Input to Output:
|
1000 VDC
|
Output to Base:
|
250 VDC
|
Input to Base:
|
1000 VDC
|
|
|
|
|
|
Environmental Characteristics
|
|
Operating Temperature:
|
-55 to 105 °C
|
Storage Temperature:
|
-40 to 125 °C
|
Over-Temperature Shut Off:
|
+106 °C Typ.
|
MTBF:
|
71,330 Hrs, 50 °C GB
|
|
|
|
|
|
Mechanical Characteristics
|
|
Dimensions:
|
6.5 x 8.0 x 1.0 inches 165 x 203 x 25.4 mm
|
Weight:
|
2.706 lbs 1230 grams
|
Case Material:
|
Steel, 0.024
|
Finish:
|
Nickel Plated
|
Mounting:
|
6-32 THD Inserts STD
|