General specifications
|
Switching function
|
Normally open/closed (NO/NC) programmable
|
Output type
|
AS-Interface
|
Rated operating distance
|
8 mm
|
Installation
|
flush
|
Assured operating distance
|
0 ... 6.48 mm
|
Reduction factor rAl
|
0.4
|
Reduction factor rCu
|
0.4
|
Reduction factor r304
|
0.7
|
Reduction factor rBrass
|
0.5
|
Slave type
|
A/B slave
|
AS-Interface specification
|
V3.0
|
Required master specification
|
≥ V2.1
|
Nominal ratings
|
Operating voltage
|
26.5 ... 31.9 V via AS-i bus system
|
Switching frequency
|
0 ... 200 Hz
|
Hysteresis
|
1 ... 15 typ. 5 %
|
Reverse polarity protection
|
reverse polarity protected
|
No-load supply current
|
≤ 25 mA
|
Switching state indicator
|
dual-LED, yellow
|
Error indicator
|
dual-LED, red
|
Functional safety related parameters
|
MTTFd
|
926 a
|
Mission Time (TM)
|
20 a
|
Diagnostic Coverage (DC)
|
0 %
|
Approvals and certificates
|
UL approval
|
cULus Listed, General Purpose
|
CSA approval
|
cCSAus Listed, General Purpose
|
CCC approval
|
CCC approval / marking not required for products rated ≤36 V
|
Ambient conditions
|
Ambient temperature
|
-25 ... 70 °C (-13 ... 158 °F)
|
Storage temperature
|
-40 ... 85 °C (-40 ... 185 °F)
|
Mechanical specifications
|
Connection type
|
Connector M12 x 1 , 4-pin
|
Housing material
|
brass, nickel-plated
|
Sensing face
|
PBT
|
Housing diameter
|
18 mm
|
Degree of protection
|
IP67
|