General specifications
|
Switching function
|
Normally closed (NC)
|
Output type
|
Two-wire
|
Rated operating distance
|
10 mm
|
Installation
|
flush
|
Output polarity
|
AC
|
Assured operating distance
|
0 ... 8.1 mm
|
Reduction factor rAl
|
0.33
|
Reduction factor rCu
|
0.28
|
Reduction factor r304
|
0.82
|
Nominal ratings
|
Operating voltage
|
20 ... 250 V
|
Switching frequency
|
0 ... 20 Hz
|
Hysteresis
|
typ. 5 %
|
Short-circuit protection
|
no
|
Voltage drop
|
≤ 8 V
|
Momentary current
(20 ms, 0.1 Hz)
|
0 ... 1600 mA
|
Operating current
|
1.5 ... 200 mA
|
No-load supply current
|
≤ 1.7 mA
|
Approvals and certificates
|
UL approval
|
cULus Listed, General Purpose
|
CSA approval
|
cCSAus Listed, General Purpose
|
CCC approval
|
Certified by China Compulsory Certification (CCC)
|
Ambient conditions
|
Ambient temperature
|
-25 ... 70 °C (-13 ... 158 °F)
|
Mechanical specifications
|
Connection type
|
terminal compartment
|
Core cross-section
|
up to 2.5 mm2
|
Housing material
|
PBT
|
Sensing face
|
PBT
|
Housing diameter
|
30 mm
|
Degree of protection
|
IP67
|
Note
|
1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V
Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is functioning correctly.
|