商铺名称:中山朗立电气有限公司
联系人:游小姐(小姐)
联系手机:
固定电话:
企业邮箱:lixun98@126.com
联系地址:中山市港口镇兴港南路17号153卡
邮编:528400
联系我时,请说是在地方电气网上看到的,谢谢!
辽宁省批发shinhwa optron继电器SMDP-5103D,3A,3~50VDC中山立讯电气有限公司直销韩国samwhadsp继电器。价格优惠。欢迎询价!
WKS-3212H04 3C 220V 12Amp. 4~32VDC
WKS-3225H04 3C 220V 25Amp.4~32VDC
WKS-3240H04 3C 220V 40Amp 4~32VDC
WKS-3250H04 3C 220V 50Amp 4~32VDC
WKS-3255H04 3C 220V 55Amp 4~32VDC
WKS-3270H04 3C 220V 70Amp 4~32VDC
WKS-3212HAC 3C 220V 12Amp 4~32VDC
WKS-3225HAC 3C 220V 25Amp 4~32VDC
WKS-3240HAC 3C 220V 40Amp 4~32VDC
WKS-3250HAC 3C 220V 50Amp 4~32VDC
WKS-3325H04 3C 440V 25Amp 4~32VDC
WKS-3340H04 3C 440V 40Amp 4~32VDC
WKS-3350H04 3C 440V 50Amp 4~32VDC
WKS-3355H04 3C 440V 55Amp 4~32VDC
WKS-3370H04 3C 440V 70Amp 4~32VDC
WKS-3325HAC 3C 440V 25Amp 85~240VAC
WKS-3340HAC 3C 440V 40Amp 85~240VAC
WKS-3350HAC 3C 440V 50Amp 85~240VAC
WKS-1212H04 2C 220V 12Amp 4~32VDC
WKS-1225H04 2C 220V 25Amp 4~32VDC
WKS-1240H04 2C 220V 40Amp 4~32VDC
WKS-1250H04 2C 220V 50Amp 4~32VDC
必须是过零点才触发,导通可控硅。(七)非过零触发-无论交流电电压在什么相位的时候都可触发导通可控硅,常见的是移相触发,即通过改变正弦交流电的导通角(角相位),来改变输出百分比。可控硅型号编辑按一机部IBI144一75的规定,普通型可控硅称为KP型可控硅整流元件(又叫KP型硅闸流管》。普通可控硅的型号采用如下格式标注:图片1图片1额定速态平均屯成系列共分为14个,如表1一5所示。正反向重复蜂值屯压级别规定1000V以下的管子每100V为一级,1000V以上的管子每200V为一级。取电压教除以100做为级别标志,如表1-6所示。通态平均电压组别依电压大小分为9组,用宇毋表示,如表1一所示。例如.KP500-12D表示的是通态平均电流为500A,额定(正反向重复峰值)电压为1200V。计数是一种简单基本的运算,计数器就是实现这种运算的逻辑电路,计数器在数字系统中主要是对脉冲的个数进行计数,以实现测量、计数和控制的功能,同时兼有分频功能,计数器是由基本的计数单元和一些控制门所组成,计数单元则由一系列具有存储信息功能的各类触发器构成,这些触发器有RS触发器、T触发器、D触发器及JK触发器等。计数器在数字系统中应用广泛,如在电子计算机的控制器中对指令地址进行计数,以便顺序取出下一条指令,在运算器中作乘法、除法运算时记下加法、减法次数,又如在数字仪器中对脉冲的计数等等。计数器可以用来显示产品的工作状态,一般来说主要是用来表示产品已经完成了多少份的折页配页工作。它主要的指标在于计数器的位数。
WKS-1255H04 2C 220V 55Amp 4~32VDC
WKS-1270H04 2C 220V 70Amp 4~32VDC
WKS-1212HAC 2C 220V 12Amp 85~240VAC
WKS-1225HAC 2C 220V 25Amp 85~240VAC.
WKS-1240HAC 2C 220V 40Amp 85~240VAC
WKS-1250HAC 2C 220V 50Amp 85~240VAC
WKS-1255HAC 2C 220V 55Amp 85~240VAC
WKS-1270HAC 2C 220V 70Amp 85~240VAC
WKS-1325H04 2C 440V 25Amp 4~32VDC
WKS-1340H04 2C 440V 40Amp 4~32VDC
WKS-1350H04 2C 440V 50Amp 4~32VDC
WKS-1355H04 2C 440V 55Amp 4~32VDC
WKS-1370H04 2C 440V 70Amp 4~32VDC
WKS-1325HAC 2C 440V 25Amp 85~240VAC
WKS-1340HAC 2C 440V 40Amp 85~240VAC
WKS-1350HAC 2C 440V 50Amp 85~240VACR
WKS-1355HAC 2C 440V 55Amp 85~240VAC
WKS-1370HAC 2C 440V 70Amp 85~240VAC
WKS-1212M04 2C 220VAC 4-32VDC
WKS-1225M04 2C 220VAC 4-32VDC
WKS-1240M04 2C 220VAC 4-32VDC
WKS-1250M04 2C 220VAC 4-32VDC
WKS-1212MAC 85-240VAC
WKS-1225MAC 85-240VAC
WKS-1240MAC 85-240VAC
WKS-1250MAC 85-240VAC
WKS-1325M04 2C 380&440VAC 4-32VDC
WKS-1340M04 2C 380&440VAC 4-32VDC
WKS-1350M04 2C 380&440VAC 4-32VDC
WKS-1325MAC 85-240VAC
WKS-1340MAC 85-240VAC
WKS-1350MAC 85-240VAC
WKS-3212M04 3C 220VAC 4-32VDC
WKS-3225M04 3C 220VAC 4-32VDC
WKS-3240M04 3C 220VAC 4-32VDC
WKS-3212MAC 85-240VAC
WKS-3225MAC 85-240VAC
WKS-3240MAC 85-240VAC
WKS-3325M04 3C 380 &440VAC 4-32VDC
WKS-3340M04 3C 380 &440VAC 4-32VDC
WKS-3325MAC 85-240VAC
WKS-3340MAC 85-240VAC
WKS-3212FRMP 3C 220VAC 12-24VDC
WKS-3225FRMP 3C 220VAC 12-24VDC
WKS-3240FRMP 3C 220VAC 12-24VDC
WKS-3212FRMN 12-24VDC
WKS-3225FRMN 12-24VDC
WKS-3240FRMN 12-24VDC
WKS-3325FRMP 3C 380 &440VAC 12-24VDC
WKS-3340FRMP 3C 380 &440VAC 12-24VDC
WKS-3325FRMN 12-24VDC
WKS-3340FRMN 12-24VDC
WKS-1212FRMP 2C 220VAC 12-24VDC
WKS-1225FRMP 2C 220VAC 12-24VD
WKS-1240FRMP 2C 220VAC 12-24VD
WKS-1212FRMN 12-24VDC
WKS-1225FRMN 12-24VDC
WKS-1240FRMN 12-24VDC
WKS-1203PBZN 1CH 220VAC 3Amp.LED 4~24VDC
WKS-1203PBZ 1CH 220VAC 3Amp
WKS-1202PB2Z 2CH 220VAC 2Amp
WKS-1210SQ 1C 220VAC.12A 4~32VDC
WKS-1212SQ 1C 220VAC.12A 4~32VDC
WKS-1220SQ 1C 220VAC.20A
WKS-1225SQ 1C 220VAC.25A
WKS-1240SQ 1C 220VAC.40A
WKS-1255SQ 1C 220VAC.55A
WKS-1270SQ 1C 220VAC.70A
WKS-1210SQAC 1C 220VAC.12A 85 ~240VAC
WKS-1212SQAC 1C 220VAC.12A 85 ~240VAC
WKS-1220SQAC 1C 220VAC.20A
WKS-1225SQAC 1C 220VAC.25A
WKS-1240SQAC 1C 220VAC.40A
WKS-1255SQAC 1C 220VAC.55A
WKS-1270SQAC 1C 220VAC.70A
WKS-1320SQ 1C 440VAC.25A 4~32VDC
WKS-1325SQ
WKS-1340SQ 1C 440VAC.40A
WKS-1355SQ 1C 440VAC.55A
WKS-1370SQ 1C 440VAC.70A
WKS-1320SQAC 1C 440VAC.25A 85 ~240VAC
WKS-1325SQAC
WKS-1340SQAC 1C 440VAC.40A
WKS-1355SQAC 1C 440VAC.55A
WKS-1370SQAC 1C 440VAC.70ACR
WKS-0007PBZ 60VDC. 7A 4~24V
WKS-0203PBZ 200VDC. 3A
WKS-0007PBZL 60VDC. 7A(LED)
WKS-0203PBZL 200VDC. 3A(LED)
WKS-0030SQ 60VDC.30A 4~32vHS-10A
WKS-0050SQ 60VDC.50A HS-20A
WKS-0080SQ 60VDC.80A HS-40A
WKS-0140SQ 100VDC.40A HS-40A
WKS-0210SQ 200VDC.10A HS-10A
WKS-0220SQ 200VDC.20A HS-20A
WKS-0330SQ 300VDC.30A HS-20A
WKS-0530SQ 500VDC.30A HS-40A
WKS-0220MAB 200VDC 20A (2-SPDT, 1a1b) 12-24VDC
WKS-1220C2M04/AC 220VAC AC,DC
WKS-0030FRMP 60VDC 30A
WKS-0050FRMP 60VDC 50A DC60V
WKS-0225FRMP 200VDC 25A DC200V
WKS-0030FRMN 60VDC 30A DC60V
WKS-0050FRMN 60VDC 50A DC60V
WKS-0225FRMN 200VDC 25A DC200V
应当由其它触点担任(例如油开关的辅助触点)。b.动断主触点性能直流有感(τ=5ms)回路,U≤250V,I≤0.5A,为50W;交流(cosФ=0.4)回路;U≤250V,I≤2A,为250VA。如果被控电路系由变流器供电并与继电器主触点并联,且当电流为4A时,其总阻抗不大于4Ω,则继电器的主触点在电流不大于50A情况下能够将这个电路分流接通与分流断开。c.过渡转换主触点性能继电器的过渡转换主触点控制电路由变流器供电,且其阻抗值在电流为3.5A时不大于4.5Ω,当电流增至150A时,继电器主触点能够将这个电路分流接通与分流断开。d.信号触点性能继电器的动合信号触点,在电压不大于250V时能接通或断开电流不大于0.2A的直流无感电路或电流不大于0.5A交流电路。2.差动保护电流互感器,3.接地保护电流互感器(零序电流互感器)保护用电流互感器主要与继电装置配合,在线路发生短路过载等故障时,向继电装置提供信号切断故障电路,以保护供电系统的。保护用电流互感器的工作条件与测量用电流保护用电流互感器保护用电流互感器互感器完全不同,保护用互感器只是在比正常电流大几倍几十倍的电流时才开始有效的工作。保护用互感器主要要求:1.绝缘可靠,2.足够大的准确限值系数,3.足够的热稳定性和动稳定性。保护用互感器在额定负荷下能够满足准确级的要求一次电流叫额定准确限值一次电流。准确限值系数就是额定准确限值一次电流与额定一次电流比。当一次电流足够大时铁芯就会饱和起不到反映一次电流的作用。
WKS-0030SQH HS-10A
WKS-0050SQH HS-20A
WKS-0080SQH HS-40A
WKS-0140SQH HS-40A
WKS-0210SQH HS-10A
WKS-0220SQH HS-20A
WKS-0330SQH HS-20A
WKS-0530SQH HS-40A
WKS-1210SQH HS-10A
WKS-1212SQH HS-10A
WKS-1220SQH HS-20A
WKS-1225SQH HS-20A
WKS-1240SQH HS-40A
WKS-1255SQH HS-300A
WKS-1270SQH HS-300A
WKS-1270SQF HS-300A/F
WKS-1210SQHAC HS-10A
WKS-1212SQHAC HS-10A
WKS-1220SQHAC HS-20A
WKS-1225SQHAC HS-20A
WKS-1240SQHAC HS-40A
WKS-1255SQHAC HS-300A
WKS-1270SQHAC HS-300A
WKS-1270SQFAC HS-300A/F
WKS-1320SQH HS-20A
WKS-1325SQH HS-20A
WKS-1340SQH HS-40A
WKS-1355SQH HS-300A
WKS-1370SQH HS-300A
WKS-1370SQF HS-300A/F
WKS-1320SQHAC HS-20A
WKS-1325SQHAC HS-20A
WKS-1340SQHAC HS-40A
WKS-1355SQHAC HS-300A
WKS-1370SQHAC HS-300A
WKS-1370SQFAC HS-300A/F
WKS-1390SQH 1P 220/380/440VAC 90A 4~32VDC
WKS-13110SQH 1P 220/380/440VAC 110 4~32VDC
WKS-13130SQF 1P 220/380/440VAC 130 4~32VDC
WKS-3390HF04 Tb 3P 220/380/440VAC 90A 4~32VDC
WKS-33110HF04 Tb 3P 220/380/440VAC 110 4~32VDC
WKS-33130HF04 Tb 3P 220/380/440VAC 130 4~32VDC
WKS-3(2)90~110A 120*268*166 ??(W)??(L)??(H)
WKS-3(2)130A 120*288*166 ??(W)??(L)??(H))
WKS-3212HH04 HS-300A
WKS-3212HF04 HS-300A/F
WKS-3225HH04 HS-320A
WKS-3225HF04Tb HS-320A/FT
WKS-3240HH04 HS-330A
WKS-3240HF04Tb HS-320A/FT
WKS-3250HH04 HS-350A
WK-3250HF04Tb HS-330A/FT
WKS-3255HF04Tb HS-330A/FT
WKS-3270HF04Tb HS-350A/FT
WKS-3212HHAC HS-300A
WKS-3212HFAC HS-300A/F
WKS-3225HHAC HS-320A
WKS-3225HFACTb HS-320A/FT
WKS-3240HHAC HS-330A
WKS-3240HFACTb HS-320A/FT
WKS-3250HHAC HS-350A
WKS-3250HFACTb HS-330A/FT
WKS-3325HH04 HS-320A
WKS-3325HF04Tb HS-320A/FT
WKS-3340HH04 HS-330A
WKS-3340HF04Tb HS-320A/FT
WKS-3350HH04 HS-350A
WKS-3350HF04Tb HS-330A/FT
WKS-3355HF04Tb HS-330A/FT
WKS-3370HF04Tb HS-350A/FT
WKS-3325HHAC HS-320A
基础顶部应预埋M24地脚螺栓,螺栓露出基础高度应不小于100mm,螺栓的预埋位置偏差不得大于±2mm;引入电缆预埋钢管的位置及规格等)。23)立杆及其主要构件的室外控制开关箱应采用不锈钢箱体,并对其表面作喷塑处理。24)立杆采用Φ159×6直缝钢管;立杆与横支臂的连接端头(0.2m)采用Φ89×4.5直缝钢管,焊接加强板(δ10钢板)保护;立杆与基础采用法兰盘加预埋螺栓连接,焊接加强板(δ10钢板)保护;横支臂与立杆端头连接方式采用法兰盘连接,并进行焊接加强板(δ10钢板)保护;立杆的中心轴线距横支臂靠路中心一侧端头的间距为5m。横支臂采用Φ89×4.5直缝钢管;且横支臂中间均匀焊接立管3根,采用Φ60×4.5钢管。应注意的问题:在工频以上频率范围内变频器输出电压为定值控制,所以电动机产生的转矩为恒功率特性,使用标准电动机与通用变频器的组合没有问题。而在工频以下频率范围内为U/f定值控制,电动机产生的转矩与负载转矩又相反倾向,标准电动机与通用变频器的组合难以适应,因此要专门设计。发热问题及对策变频器发热是由于内部的损耗而产生的,以主电路为主,约占98%,控制电路占2%。为保证变频器正常可靠运行,必须对变频器进行散热。主要方法有:(1)采用风扇散热:变频器的内装风扇可将变频器箱体内部散热带走。(2)环境温度:变频器是电子装置,内含电子元件机电解电容等,所以温度对其寿命影响较大。通用变频器的环境运行温度一般要求-10℃~+50℃。
WKS-3325HFACTb HS-320A/FT
WKS-3340HHAC HS-330A
WKS-3340HFACTb HS-320A/FT
WKS-3350HHAC HS-350A
WKS-3350HFACTb HS-330A/FT
WKS-1212HH04 HS-300A
WKS-1225HH04 HS-300A
WKS-1240HH04 HS-320A
WKS-1250HH04 HS-330A
WKS-1255HH04 HS-330A
WKS-1270HH04 HS-350A
WKS-1270HF04Tb HS-330A/FT
WKS-1212HHAC HS-300A
WKS-1240HHAC HS-320A
WKS-1250HHAC HS-330A
WKS-1255HHAC HS-330A
WKS-1270HHAC HS-350A
WKS-1340HHAC
WKS-1350HHAC
WKS-1370HHAC
WKS-3212HHAC
WKS-3225HHAC
WKS-3240HHAC
WKS-3250HHAC
WKS-3325HHAC
WKS-3340HHAC
WKS-3350HHAC
WKS-1270HFACTb HS-330A/FT
WKS-1325HH04 HS-300A
WKS-1340HH04 HS-320A
WKS-1350HH04 HS-330A
WKS-1355HH04 HS-330A
WKS-1370HH04 HS-350A
WKS-1370HF04Tb HS-330A/FT
WKS-1325HHAC HS-300A
WKS-1340HHAC HS-320A
WKS-1350HHAC HS-330A
WKS-1355HHAC HS-330A
WKS-1370HHAC HS-350A
WKS-1370HFACTb HS-330A/FT
(T.P.R)
WKS-1212SQTM 220VAC 12Amp 0-500KΩ
WKs-1225SQTM 220VAC 25Amp 0-500KΩ
WKS-1240SQTM 220VAC 40Amp 0-500KΩ
WKs-1325SQTM 20VAC 25Amp 0-500KΩ
WKS-1340SQTM 220VAC 40Amp 0-500KΩ
(T.P.R )
WKS-1212SQTMH HS-10A 0-500KΩ
WKS-1225SQTMH HS-20A 0-500KΩ
WKS-1240SQTMH HS-40A 0-500KΩ
WKS-1325SQTMH HS-20A 0-500KΩ
WKS-1340SQTMH HS-40A 0-500KΩ
电源
WK-15AF 15 1 90 ~260 VAC
WK-15AB
WK-15BX
WK-15CX
WK15-3B
WK15-3C
WK-30AF
WK-30AB
WKS-30BX
WKS-30CX
WKS-303BX
WKS-30-3X
WK-50AF 50 1 90 ~ 130/180 ~ 260VAC
WK-50AB 2
WK-50BD
WK50-3X 96*153*43(W*L*H)
WK-75AF
WK-75AB
WK-75BD
WK-60BX
WK-60CX
WK-100AF
WKS-90AB
WKS-100CX
WKS-100AM
WK-100DM
WK-150AF
WK-150CX
WK-130MR
请不要取出存储媒体,否则会破坏数据。其他使用注意事项,请参见所使用的存储媒体所带的使用说明书。产品采购要点编辑无纸记录仪经过了以上介绍近20多年的进化,从单一功能发展到五花八门,应用行业也越来越多,如化工行业,运输行业,行业,工业炉行业,水处理行业,电力行业等,许多厂家看到了无纸记录仪的发展市场,也纷纷进入了无纸记录仪的生产或销售,但许多小企业生产的产品技术含量小,为了追求利润,采用劣质元器件生产低质量产品来充斥市场,这些产品精度低,稳定性差,外观粗糙,生产质量参差不齐,无纸记录仪市场也逐渐进入纷乱状态。就如何选择一款优质的无纸记录仪作出简单的介绍,让您采购的产品不至于为假冒或劣质产品,选择无纸记录仪可以从以下几个方面分析:首先需要了解一下记录仪生产厂家的情况。电压整定范围:有辅源(0.1-99.9V,40-450V)无辅源(19-130V,85-265V,180-440V)功率消耗:交流回路功耗小于1VA(交流额定值100V时)整定误差a、在整定范围内,整定平均误差的值不大于3%,平均误差=(5次测量平均值-整定值)/整定值×。b、在基准条件下,同一整定值上测量的5次动作值的值和值应不大于的4%。c、在-10℃~50℃的温度下,任一整定点误差的值应不大于整定值的4%。d、在辅助电压80~110%变化范围内,任一整定值整定误差的值应不大于4%。动作时间a、过电压继电器:1.2倍整定值的动作时间不大于25ms;2倍整定值的动作时间不大于20ms;
WKS-140MR
WKS-102CT 106*199*50(W*L*H)
WKS-128M
WKS-150MR
WK-903M
WK-903MX
WK-200AF
WK-200CX
WK-160MR
WK-200MR
WK-250A~F 100*200*90
WK-300A~F
WK-400A~F
WKS-500A~F
WKS-600A~F
WKS-750A~F
WKS-1000A~F
WKS-1200A~F
WKS-1500A~F
WKS-1210SQ
WKS-1220SQ, WKS-1225SQ
WKS-1320SQ, WKS-1325SQ
WKS-1240SQ, WKS-1340SQ
WKS-1255SQ, WKS-1270SQ
WKS-1355SQ, WKS-1370SQ
WKS-3212H, WKS-1212H
WK-1225H, WKS-1325H
HS-300A/F DC24V60*60mm WKS-1270SQ, WKS-1370SQ
WKS-3212H HS-320A WKS-3225H , WKS-3325H
WKS-1240H,
WKS-1340H HS-320A/FT Bolt DC24V,AC22080*80mm
WKS-3225H , WKS-3240H
WKS-3325H , WKS-3240H
WKS-1250H , WKS-1350H
WKS-3240H , WKS-3340H
WKS-1250H , WKS-1255H
WKS-1350H , WKS-1355H
HS-330A/FT DC24V,AC22080*80mm
WK-3250H , WK-3255H04
WKS-3350H , WKS-3355H04
WKS-1270H , WKS-1370H
WK-3250H , WKS-3350H
WKS-1270H , WKS-1370H
WK-3270H04, WK-3370H04
WKS-BKT
DSP-VPFR22/44/69
DSP-VIP-PL
DSP-VIP-PM
DSP-VIP-CM
DSP-VIP-CL
DSP-VIP-RTM
DSP-VIP-5EM/5TM/5CM
DSP-VIP-5EL/5TL/5CL
DSP-COM,CCM(485),CTM(4-20mA)
DSP-COL,CCL(485),CTL(4-20mA)
DSP06-3ESSG
DSP06-3ESS(30,60,120)
DSP-10SP, 20SP, 30SP
DSP-SP 01
DSP-30ES
DSP-06ES, (06, 10, 30, 50)
DSP-06ES2, 30-ES2, 60-ES2, 120-ES2
DSP06-SS (30, 60, 120)
DSP-SS 120
DSP-326L DSP-346L DSP-336L DSP-143R DSP-146L DSP-136L DSP-126L DSP-123R DSP-133R
DSP-DGFR DSP-VIP-4EL05Z7-DC DSP-SDTR DSP-UVR110 DSP-UVR220 DSP-UVR380 DSP-OVR380
DSP-OVR220 DSP06-UCR, (30, 60) DSP-WL252R-S DSP-GR 600
DSP-E2CV DSP-NGR44 DSP-NGR22 DSP-APS-BMH DSP-APS-BRH
它是旋转180°后的二次电流向量与一次电流向量之间的相位差。规定二次电流向量超前于一次电流向量δ为正值,反之为负值,用分(’)为计算单位。2.10热稳定及动稳定倍数:电力系统故障时,电流互感器受到由于短路电流引起的巨大电流的热效应和电动力作用,电流互感器应该有能够承受而不致受到破坏的能力,这种承受的能力用热稳定和动稳定倍数表示。热稳定倍数是指热稳定电流1s内不致使电流互感器的发热超过允许限度的电流与电流互感器的额定电流之比。动稳定倍数是电流互感器所能承受的电流瞬时值与其额定电流之比。类型区分编辑按用途分类按照用途不同,电流互感器大致可分为两类[4]:测量用电流互感器(或电流互感器的测量绕组):在正常工作电流范围内。为0.1秒,不能有效地保护晶闸管)。设计时可依据厂家提供的产品样本,根据软起动器的额定电流选择相应的快熔断器。3)当软起动器使电机制动停机时,只是晶闸管不导通,在电机与电源之间并没有形成电气隔离。如果此时检修软起动器之后的线路、电机,那是不的。所以在电机一次控制回路中应在软起动器之前增加断路器。4)由于信息及网络技术的飞速发展,现代的楼宇特别是智能建筑中电子设备日益增多,它们对电网的质量有较高的要求。而由于软起动器采用了可控硅等非线性器件,所以当软起动器功率较大或者台数较多时,产生的高次谐波将对电网造成不良的影响并对建筑物内的电子设备产生干挠。此时可装设旁通接触器。在软起动器使电机平稳起动至正常转速后。